HI733 Ammonia High Range Checker (0.0-99.9 ppm)

69,00 

The Hanna Ammonia High-Range (0 to 99.9 ppm) Checker® bridges the gap between simple chemical test kits and professional instrumentation. Chemical test kits have limited accuracy and resolution since they rely upon the human eye to discern differences in color. Professional instrumentation incorporates a light source such as an LED or tungsten lamp with a filter and a light sensing detector to precisely determine ion concentration. Professional instrumentation offers greater resolution and accuracy but can cost hundreds of dollars. The Hanna Ammonia High Range Checker® uses a fixed wavelength LED and silicon photo detector to provide the accuracy of professional instrumentation at the affordable price of a chemical test kit.

  • Compact, Portable Design
  • Built-in Timer
  • One-Button Operation
Κωδικός προϊόντος: HI733 Κατηγορίες: , Ετικέτα:

Πληροφορίες προϊόντος

The HI733 Checker® HC (Handheld Colorimeter) provides a simple, accurate and cost-effective way to measure ammonia. Present in water as a component of the nitrogen cycle, ammonia is excreted from animals and other organisms such as heterotrophic bacteria, actinomycetes, and fungi during the metabolism of proteins and amino acids. Generally present in small quantities in unpolluted waters, higher levels indicate organic pollution and is toxic to aquatic life. Designed as a more accurate alternative to chemical test kits, the HI733 provides quick, accurate results in four easy steps:

*1 ml of sample is added to a cuvette with 9 ml of reagent “B”. The cuvette is then placed in the meter and the button pressed to zero.

Features at-a-glance:

  • Easier to use and more accurate than chemical test kits
  • Dedicated to a single parameter
  • Small size, big convenience
  • Ideal for: Water Quality, Aquaculture, Education, Industrial

 

Specifications

Specifications
Range0.0 to 99.9 ppm as NH₄⁺
Resolution0.1 ppm
Accuracy @ 25C/77F1.0 ppm 5% of reading
Light SourceLED @ 470 nm
Light Detectorsilicon photocell
Methodadaptation of the ASTM Manual of Water and Environmental Technology D1426-92, Nessler Method. The reaction between ammonia and reagents causes a yellow tint in the sample.
Environment0 to 50C (32 to 122F); RH max 95% non-condensing
Battery Type(1) 1.5V AAA
Auto-offafter ten minutes of non-use
Dimensions81.5mm x 61mm x 37.5mm (3.2" x 2.4" x 1.5”)
Weight64 g (2.25 oz.)
Ordering InformationHI733 Checker is supplied with (2) sample cuvettes with caps, ammonia reagent starter kit for 25 tests (1 bottle of HI733A-0 and 1 bottle of HI733B-0), syringe with tip, dropper, battery, instructions and quick start guide