HI6221- Research Grade pH/ORP Meter with CAL Check™

924,00 

HI6221 is a streamlined benchtop meter with a large touch screen display, comprised of a housing and an integrated pH / ORP measurement module.

Compact and easy to operate, the benchtop meter is delivered with Hanna Instruments HI1131B double junction combination pH electrode, together with HI7662-TW temperature probe.

HI1131B is a glass body, double junction, refillable pH electrode with an indicating sensor made of High Temperature (HT) glass. The double junction reference and HT glass design allow the HI1131B to be used in a wide variety of applications including samples with metals and elevated temperatures. Probe connection to the unit is secured through a galvanically isolated BNC connection. HI7662-TW stainless steel temperature probe allows the meter to automatically temperature compensate (ATC) pH measurements.

Κωδικός προϊόντος: HI6221 Κατηγορίες: , , , Ετικέτα:

Πληροφορίες προϊόντος

This system responds to a complex range of measurement and monitoring requirements, providing accuracy, reproducibility, and reliability. HI6221 is supplied with an electrode holder that has a flexible arm. The holder can be mounted quickly and provides secure support for electrodes while taking measurements in sample containers.

User interface

  • 7-inch capacitive touch screen with multi-touch support
  • Capacitive touch back, home and system menu keys
  • User-friendly icons and symbols allow users to easily navigate and interpret the instrument functions.
  • The user can select between five different views:
    • Basic measurement configuration
    • Simple GLP with calibration information
    • Full GLP with electrode status and calibration point details
    • Live updated, interactive graph
    • Tabulated data with date, time, and notes

Measurement

  • Measure pH/mV (pH) or mV/Rel.mV (ORP) with temperature
  • Application-specific profiles allow quick and direct measurement without the need to update the sensor and system settings
  • Active log during measurement o Measurement stability indicator (using the Stability Criteria setting)
  • Reading modes: direct and direct/autohold
  • Temperature compensation can be Automatic (using temperature probe) or set manually
  • Audible and/or alarm messages for measurements outside of predefined limits
  • Galvanic isolation for pH/ORP measurement

Calibration

  • 5-point pH calibration with automatic recognition for standard buffers (Hanna and NIST buffers)
  • Choice of standard or custom buffers for calibration
  • Non-volatile memory saves data and settings

Logging

  • Data log collection of at least 1,000,000 data points (with time and date stamp)
  • Logging types: manual, automatic, autohold
  • Sample ID for manual and Autohold data

Connectivity features & services

  • Transfer logged data to a USB thumb drive
  • Log files that include measurements and calibration data (as .csv file)
  • FTP and email for log export via Ethernet and Wi-Fi connection
  • USB type A for USB stick, keyboard, and printer
  • USB type C for USB stick and PC connection

Capacitive touch screen with multi-touch support

The benchtop unit has a 7-inch color display with 800 x 480p resolution. The capacitive, multi-touch screen supports video playback and data plotting.

System Menu key

This key will enter the system menu where User accounts, System Settings, and Logging can be configured. The Help menu is also accessed on the system menu screen.

Measurement setup menu

Opens sensor setup parameters.

Direct/Autohold readings

When Direct/Autohold is selected, measurement reading is held on display when measurement stability is reached. This option removes the subjective nature of stability as a measurement that has not reached equilibrium will not be used.

When not selected, sample measurements are displayed continuously.


 

HI6221 is supplied with:

  • HI1131B pH electrode; HI7662-TW temperature probe
  • pH calibration starter kit consisting of:
    • pH 4.01 buffer solution sachet (2 pcs.)
    • pH 7.01 buffer solution sachet (4 pcs.)
    • pH 10.01 buffer solution sachet (2 pcs.)
  • HI700601 electrode cleaning solution sachet (2 pcs.)
  • HI7082 3.5M KCl electrolyte solution (30 mL)
  • HI764060 electrode holder
  • Capillary pipette
  • 24 VDC power adapter
  • USB-C to USB-A cable
  • Quick reference guide with instrument quality certificate.

Specifications

SKUHI6221-02
Product NameAdvanced pH/ORP Benchtop Meter- HI6221-02
Quote RequiredNo
pH Range-2.0 to 20.0 pH; -2.00 to 20.00 pH; -2.000 to
pH Range20.000 pH
pH Resolution0.1 pH; 0.01 pH; 0.001 pH
pH Accuracy±0.1 pH; ±0.01 pH; ±0.002 pH (±1 last significant digit)
mV Range±2000.0 mV
mV Resolution1 mV; 0.1 mV
mV Accuracy±0.2 mV ±1 last significant digit
Temperature Range-20.0 to 120.0 °C; -4.0 to 248.0 °F; 253.0 to 393.0 K
Temperature Resolution0.1 °C / 0.1 °F / 0.1 K
Temperature Accuracy±0.2 °C / ±0.4 °F / ±0.2 K
Relative mV offset range±2000.0 mV
pH Calibration Calibration pointsUp to 5
pH Calibration TypeAutomatic; Semiautomatic; Manual
pH Calibration Standard buffersHanna and NIST
pH Calibration Standard bufferspH 1.68, 3.00, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45"
pH Calibration Custom buffersUp to 5
pH Calibration Custom groupUp to 5
pH Calibration 1st calibration pointOffset or Points (user setting)
pH Calibration ReminderDisabled
pH Calibration ReminderDaily
pH Calibration ReminderPeriodic
Temperature CompensationAutomatic or Manual
Reading ModesDirect; Direct/Autohold
Reading Stability criteriaAccurate; Medium; Fast
Reading Isopotential7.000 or 4.010
Reading Sampling rate1000 ms
pH Views BasicMeasurement (pH, mV, Rel.mV, Abs.mV)
pH Views BasicTemperature, Stability status
pH Views Simple GLPBasic view information
pH Views Simple GLPLast calibration date, electrode offset, average slope, and electrode condition
pH Views Full GLPSimple GLP information and calibration point details
pH Views TableMeasurements updated every second are displayed in table
pH Views Graph (Plot)pH (or mV) and temperature versus time graph can be panned or zoomed (pinch-to-zoom technology)
Logging TypeAutomatic, Manual, Autohold
Logging Number of records50 000 maximum per file / Stores at least 1 000 000 data points per user"
Logging Automatic interval1, 2, 5, 10, 30 seconds
Logging Automatic interval1, 2, 5, 10, 15, 30, 60, 120, 150, 180 minutes"
Logging Sample IDIncremental mode
Logging Export option.csv file format
Logging Export optionUsers Up to 9 users and admin. account (default)
Connectivity USB-A2 ports for keyboard input or USB thumb drive
Connectivity USB-C1 port for PC connectivity and USB-C type thumb drive
Connectivity Wi-Fi & EthernetFTP / Web server Log transfer and download Email
Connectivity RS232Connecting peripherals
Power supplyDC adapter 100-240AC to 24VDC 2.5A
Environment0 - 50 °C / 32 - 122 °F / 273 - 323 K maximum 95% RH non-condensing
Dimensions205 x 160 x 77 mm (8.0 x 6.2 x 3.0 “)
WeightApproximately 1.2 kg (2.65 lbs.)