HI98494 is a waterproof portable logging multiparameter meter that monitors up to 12 different water quality parameters including 6 measured and 6 calculated.  The microprocessor based multi-sensor probe allows for the measurement of key parameters including pH, ORP, conductivity, dissolved oxygen, and temperature. The probe transmits readings digitally to the meter, where data points can be displayed and logged. Data logged in the meter can be transferred by Bluetooth® to a smart device with the Hanna Lab App installed. The HI98494 is supplied with all necessary accessories and packaged in a durable carrying case.

  • Bluetooth® Connectivity
  • OPDO: Optical Dissolved Oxygen Technology
  • 12 Parameter Dot Matrix Display
Κωδικός προϊόντος: HI98494 Κατηγορίες: , Ετικέτα:

Πληροφορίες προϊόντος

Measurements & Logging

Measure up to 12 parameters. Don’t lose important data with automatic interval logging of up to 45,000 samples or choose to log-on-demand to store measurement data for key points.

Dual Power Source

The meter operates on a built-in lithium-ion battery and will automatically switch to AA alkaline batteries for at least 200 hours of testing.

GLP Data

For better traceability, calibration information is recorded along with a time and date stamp and stored with logged data.

Quick-Calibration

Quick Calibration provides a speedy, single point calibration for pH, conductivity, and dissolved oxygen. Standard calibration options are also available.

Built to be Durable

Designed to withstand the knocks, drops, and spills of real life, the IP67 body ensures top performance in any environment. These meters are protected against dust and water intrusion from any direction.

Quick Connect Probe

A Quick Connect DIN connector makes attaching and removing the probe simple and easy. The rubber coating protects the cable and provides a water-tight seal without twisting.

 

Data Transfer & Charging

The USB Type-C port provides for easy data transfer to memory stick, PC, or other device and is used to charge internal lithium-ion battery.

Digital Probe

Digital probe with built-in temperature sensor and three ports for pH (ORP), EC and optical DO sensors. Once connected, the meter automatically recognize the sensors.

Multiparameter Probe and Sensors

Sensor replacement is quick and easy with field replaceable, screw type connectors and are color-coded for easy identification.

 

 

 

Connect in the Field

Connect wirelessly via Bluetooth® to your smart device running the Hanna Lap App.

Features

Measurement & Graphing

Select the measurement units to be displayed on your smart device. For trend analysis, take a look at the graph of your logged data.

Good Laboratory Practice (GLP)

Comprehensive GLP data can be reviewed for all parameters when the logged data is downloaded to your smart device.

Sort & Share

Group your data by time or notation. Email it for storage or share it with friends or colleagues.

 

 

 

 

Specifications

SKUHI98494-web
Product NameMultiparameter Bluetooth® portable pH/EC/OPDO Meter - HI98494
Stock Status MessageShips within 5-6 Weeks
Quote RequiredNo
pH Range0.00 to 14.00 pH*
pH Resolution0.01 pH
pH Accuracy± 0.02 pH
pH Calibrationone point, using HI9828-25 Quick calibration solution up to three points using five standard buffers (pH 4.01, 6.86, 7.01, 9.18, 10.01) and one custom buffer
pH Temperature Compensationautomatic from -5 to 50 °C (23 to 122 °F)
ORP Range± 2000.0 mV
ORP Resolution0.1 mV
ORP Accuracy± 1.0 mV
ORP Calibrationone point (relative mV)
mV RangepH in mV ± 600.0 mV
mV ResolutionpH in mV 0.1 mV
mV AccuracypH in mV
mV Relative Offset± 0.5 mV
EC Range0 to 200 mS/cm (absolute EC up to 400 mS/cm)
EC Resolutionauto-ranging
EC Accuracy±1 % of reading or ±1 μS/cm, whichever is greater
EC CalibrationOne point, using HI9828-25 Quick calibration solution One point, using six standard solutions (84 μS/cm, 1413 μS/cm, 5.00 mS/cm, 12.88 mS/cm, 80.0 mS/cm, 111.8 mS/cm) or custom point
TDS Range0 to 400000 ppm (mg/L); (the maximum value depends on the TDS factor)
TDS Resolutionmanual
TDS Accuracy±1 % of reading or ±1 ppm (mg/L), whichever is greater
TDS CalibrationBased on conductivity calibration
EC/TDS Temperature Compensationautomatic from -5 to 50 °C (23 to 122 °F)
Temperature Correction Coefficient0.00 to 6.00 %/°C
EC to TDS Conversion Factor0.00 to 1.00
Reference Temperature20 °C or 25 °C
Cell Typepotentiometric four pole
EC/TDS Multi-range Measurement Modesyes
Salinity (PSU) Range0.00 to 70.00 PSU
Salinity (PSU) Resolution0.01 PSU
Salinity (PSU) Accuracy±2% of reading or ±0.01 PSU, whichever is greater
Salinity (PSU) CalibrationOne point, using a custom solution
Salinity (Seawater Sigma) Range0.0 to 50.0 σt, σ0, σ15
Salinity (Seawater Sigma) Resolution0.1 σt, σ0, σ15
Salinity (Seawater Sigma) Accuracy±1.0 σt, σ0, σ15
Salinity (Seawater Sigma) CalibrationBased on conductivity or salinity calibration
Resistivity Range0 to 999999 Ω·cm
Resistivity Resolution1 Ω·cm; 0.1 kΩ·cm; 0.0001 MΩ·cm
Resistivity CalibrationBased on conductivity or salinity calibration
Dissolved Oxygen Measurement Typeoptical luminscent technology
Dissolved Oxygen Range0.00 to 50.00 mg/L
0.0 to 500.0 % saturation
Dissolved Oxygen Resolution0.01 mg/L
0.1 % saturation
Dissolved Oxygen Accuracy±1.5 % of reading ± 0.01 mg/L from 0.00 to 20.00 mg/L
±5 % of reading from 20.00 to 50.00 mg/L
±1.5 % of reading ±0.1 % from 0.0 to 200.0 % saturation
±5 % of reading from 200.0 to 500.0 % saturation
Dissolved Oxygen Calibrationone point, quick calibration in water-saturated air
One or two points, at 100 % and 0 %
One point, using a custom solution (% saturation or mg/L )
Dissolved Oxygen Temperature Compensationautomatic from -5 to 50 °C (23 to 122 °F)
Altitude Compensationautomatic
Temperature Range-5.00 to 50.00 °C, 23.00 to 122.00 °F, 268.15 to 323.15 K
Temperature Resolution0.01 °C; 0.01 °F; 0.01 K
Temperature Accuracy±0.15 °C; ±0.27 °F; ±0.15 K
Temperature CalibrationOne point using a custom value
pH ElectrodeHI7698194-0
pH/ORP ElectrodeHI7698194-1 (supplied)
EC/TDS ProbeHI7698194-3 (supplied)
DO ProbeHI7698494-5 (supplied)
Multi-parameter ProbeHI7698494 (supplied)
Temperature Probebuilt-in
Logging Typeinterval and log on demand
Logging Memory50000 records, interval logging
20000 records, log-on-demand of all parameters
Logging Interval1 second to 3 hours
ConnectivityBluetooth®, USB-C (mass-storage host), USB-C (mass-storage device)
Automatic Shut-Off5, 10, 15, 20, 30, 60 minutes or disabled
GLPyes
Displaybacklit dot matrix
Battery Type/LifeMinimum 200 hours (AA batteries, without backlighting and Bluetooth®)
Minimum 50 hours (Li-ion battery, without backlighting and Bluetooth®)
IP ProtectionIP67
Environment0 to 50 °C (32 to 122 °F); RH 100 %
Dimensions185 x 93 x 35.2 mm (7.3 x 3.6 x 1.4”)
Weight435 g (13.3 oz)
Ordering InformationHI98494 is delivered in a rugged thermoformed carrying case and is supplied with, HI7698494 multi-sensor probe, HI7698194-1 pH/ORP sensor, HI7698194-3 EC/TDS/Resistivity/Salinity sensor, HI7698494-5 optical DO sensor, HI764113-1 DO smart cap with o ring, HI7698295 short protective probe shield, HI7698290 calibration beaker, HI9828-20 quick calibration standard solution (230 mL), HI7040 Zero oxygen solution set (120 mL), HI76984942 probe maintenance kit, HI920016 USB cable, 1.5V AA alkaline batteries (4 pcs.), instrument quality certificate, probe quality certificate, DO smart cap quality certificate, and instruction manual.
Notes*The range may be limited by the sensor’s limits.
Atmospheric Pressure Range450.0 to 850.0 mmHg 17.72 to 33.46 inHg 600.0 to 1133.2 mbar 8.702 to 16.436 psi 0.5921 to 1.1184 atm 60.00 to 113.32 kPa
Atmospheric Pressure Resolution0.1 mmHg; 0.01 in Hg; 0.1 mbar 0.001 psi; 0.0001 atm; 0.01 kPa
Atmospheric Pressure Accuracy±3.0 mmHg within ±15°C from calibration temperature
Atmospheric Pressure CalibrationOne point using a custom value