HI98193 Waterproof Portable Dissolved Oxygen

818,00 

The HI98193 is a rugged, portable dissolved oxygen (DO) meter designed for demanding applications. This professional, waterproof meter complies with IP67 standards and measures DO, barometric pressure, BOD and temperature. The HI98193 is supplied complete with all accessories to perform a DO measurement packaged into a durable carrying case.

  • Preformed PTFE Membrane
  • Quick Connect
  • Ergonomic, One-Handed Operation
Κωδικός προϊόντος: HI98193 Κατηγορίες: , Ετικέτα:

Πληροφορίες προϊόντος

For the measurement of DO, the HI98193 is supplied with the HI764073 polarographic dissolved oxygen probe. This probe uses preformed PTFE membrane caps that are field replaceable. The probe connects to the meter with a unique quick connect waterproof DIN connector allowing for a secure attachment without a threaded connect that is also easy to remove.

The HI98193 portable DO meter has extended ranges of up to 50 ppm and 600% saturation. When measuring dissolved oxygen, compensations for pressure, temperature and salinity are essential for an accurate reading.

Pressure compensation can be done automatically with the meter’s built-in barometer or by manual entry. Calibration of the built-in barometer is done to one point by entering the value of a reference barometer. Pressure is displayed in user-selectable units including mmHg, inHg, atm, psi, kPa, and mbar.

The HI764073 DO probe has a built-in temperature sensor for automatic temperature compensation. The temperature sensor can be calibrated to one or two points. Manual entry of salinity values allows for the salinity compensation of dissolved oxygen readings in saline waters.

Other features include built-in methods and calculations for the measurement of Biological Oxygen Demand (BOD), Oxygen Uptake Rate (OUR) and Specific Oxygen Uptake Rate (SOUR).

The HI98193’s log on-demand feature allows users to store up to 400 readings. This data can then be transferred to a PC with the HI920015 USB cable and HI92000 software.

GLP data is accessible by a fixed dedicated key this data includes date, time, pressure, calibrated value, temperature and salinity value of the last calibration.

Access help at any time at the press of a dedicated button and view content specific information based on the screen that is currently being viewed.

The high contrast graphic LCD is easy to read outdoors in bright sunlight to low-lit areas with the backlight. A combination of dedicated and virtual keys allows easy, intuitive operation in a choice of languages.

The compact, durable HI760193 carrying case is thermoformed to hold all necessary components for taking a field measurement, including the meter and electrode, beakers, buffer solutions, cleaning solutions and storage solutions.

Quick Connect

Details

For the measurement of DO the HI98193 is supplied with the HI764073 polarographic dissolved oxygen probe. This probe uses preformed PTFE membrane caps that are field replaceable. The probe connects to the meter with a unique quick connect waterproof DIN connector allowing for a secure attachment without a threaded connect that is also easy to remove.

The HI98193 portable DO meter has extended ranges of up to 50 ppm and 600% saturation. When measuring dissolved oxygen, compensations for pressure, temperature and salinity are essential for an accurate reading.

Pressure compensation can be done automatically with the meter’s built-in barometer or by manual entry. Calibration of the built in barometer is done to one point by entering value of a reference barometer. Pressure is displayed in user-selectable units including mmHg, inHg, atm, psi, kPa, and mbar.

The HI764073 DO probe has a built in temperature sensor for automatic temperature compensation. The temperature sensor can be calibrated to one or two points. Manual entry of salinity values allows for the salinity compensation of dissolved oxygen readings in saline waters.

Other features include built in methods and calculations for the measurement of Biological Oxygen Demand (BOD), Oxygen Uptake Rate (OUR) and Specific Oxygen Uptake Rate (SOUR).

The HI98193’s log on-demand feature allows users to store up to 400 readings. This data can then be transferred to a PC with the HI920015 USB cable and HI92000 software.

GLP data is accessible by a fixed dedicated key this data includes date, time, pressure, calibrated value, temperature and salinity value of the last calibration.

Access help at any time at the press of a dedicated button and view content specific information based on the screen that is currently being viewed.

The high contrast graphic LCD is easy to read outdoors in bright sunlight to low-lit areas with the backlight. A combination of dedicated and virtual keys allows easy, intuitive operation in a choice of languages.

The compact, durable HI760193 carrying case is thermoformed to hold all necessary components for taking a field measurement, including the meter and electrode, beakers, buffer solutions, cleaning solutions and storage solutions.

Features/Benefits:

Ergonomic, rugged, waterproof (IP67) design

Choice of units

  • Display dissolved oxygen in % saturation or mg/L

Built in Barometer

  • Automatic barometric pressure compensation with 1 point calibration
  • Displays pressure in user-selectable units (mmHg, inHg, atm, psi, kPa, mbar)

Built-in temperature sensor

  • Automatic temperature compensation with one or two point temperature calibration
  • Displays temperature in °C or °F

Salinity compensation

  • Manual salinity compensation with a selectable salinity value

Built-in calculations

  • Determination of Biochemical Oxygen Demand (BOD), Oxygen Uptake Rate (OUR) and Specific Oxygen Uptake Rate (SOUR)

 

Polarization

  • Automatic polarization of polarographic probe at startup to ensure that the probe is ready to use when measurement screen is displayed

Membrane caps

  • Ready-to-use field replaceable PTFE membrane caps

Log-on-demand

  • Store measurement data at the press of a button

GLP features

  • GLP data provides calibration data including date, time, pressure, calibrated value, temperature and salinity value of the last calibration

Contextual help at the press of a button

Backlit, Graphic LCD

Specifications

Specifications
DO Range0.00 to 50.00 ppm (mg/L); 0.0 to 600.0% saturation
DO Resolution0.01 ppm (mg/L); 0.1% saturation
DO Accuracy1.5% of reading 1 digit
DO Calibrationautomatic one or two point at 100% saturation (8.26 mg/L) and 0% saturation (0 mg/L).
Atmospheric Pressure Range450 to 850 mmHg
Atmospheric Pressure Resolution1 mmHg
Atmospheric Pressure Accuracy 3 mmHg within 15% from the calibration point
Atmospheric Pressure Calibrationone point at any in range pressure value
Temperature Range-20.0 to 120.0C (-4.0 to 248.0F)
Temperature Resolution0.1C (0.1F)
Temperature Accuracy0.2C; 0.4F (excluding probe error)
Temperature Calibrationone or two point at any in range temperature value
Temperature Compensationautomatic from 0 to 50C (32 to 122F)
Measurement Modesdirect DO; BOD (biochemical oxygen demand); OUR (oxygen uptake rate); SOUR (specific oxygen uptake rate)
Barometric Compensationautomatic from 450 to 850 mmHg
Salinity Compenstaionautomatic from 0 to 70 g/L
Electrode/ProbeHI764073 polarographic DO probe with protective sleeve, internal temperature sensor, DIN connector and 4m (13’) cable (included)
Log-on-demandup to 400 samples
PC Connectivityopto-isolated USB with optional HI 92000 software and micro USB cable
Battery Type/Life1.5V AA batteries (4) / approximately 200 hours of continuous use without backlight (50 hours with backlight)
Auto-offuser selectable: 5, 10, 30, 60 min or can be disabled
Environment0 to 50C (32 to 122F); RH 100% (IP67)
Dimensions185 x 93 x 35.2 mm (7.3 x 3.6 x 1.4”)
Weight400 g (14.2 oz.)
Ordering InformationHI98193 is supplied with HI764073 DO probe, preformed PTFE membrane cap (2), HI7041S electrolyte solution (30 mL), HI7040 bicomponent zero oxygen solution, 100 mL plastic beakers (2), HI92000 PC software, HI920015 micro USB cable, 1.5V AA batteries (4), instruction manual, quick start guide, instrument quality certificate and HI760193 rugged carrying case.