HI 93703 Portable Turbidity Meter

882,00 

HI 93703 series are microprocessor based turbidity meters that provide laboratory accuracy for field turbidity measurements.

The HI 93703 is easy to calibrate (with 3 point calibration) using AMCO-EPA standards and is ISO 7027 compliant.

Κωδικός προϊόντος: ΗΙ93703 Κατηγορίες: , Ετικέτα:

Πληροφορίες προϊόντος

HI 93703 series are microprocessor based turbidity meters that provide laboratory accuracy for field turbidity measurements.

The HI 93703 is easy to calibrate (with 3 point calibration) using AMCO-EPA standards and is ISO 7027 compliant.

  • GLP Features
  • 3 point calibration
  • Logging for up to 199 measurements (HI 93703-11)
  • PC Connectivity (HI 93703-11)

HANNA instruments has chosen 10 FTU* as the calibration point because it is the value that best fits the water turbidity measurements in different applications, from drinking water to wastewater treatment. HANNA instruments uses the primary standard AMCO-AEPA-1 to avoid all formazine-related problems. Formazine is a very toxic, unstable substance which requires particular care: its standards have to be prepared only a few minutes before performing the calibration, and cannot be reused because of their short life. HANNA AMCO-AEPA-1 standards are extremely stable, can be reused, and last up to six months if free from contamination. HI 93703 can be used with both standards.

The HI 93703-11 enhanced version features a real-time clock, logging for up to 199 measurements and PC compatibility via the RS232 interface and Windows® compatible HI 92000 software.

Both versions meet the requirements of GLP (Good Laboratory Practice) protocols for last calibration data storage.

Order Information:
HI 93703 is supplied complete with glass cuvette, batteries and instructions.
HI 93703-11 is supplied complete with glass cuvette, batteries and instructions.
HI 93703C, kit including HI 93703 and HI 731313 maintenance kit.

Specifications

Specifications
Range0.00 to 50.00 FTU;
50 to 1000 FTU
Resolution0.01 FTU (0.00 to 50.00 FTU);
1 FTU (50 to 1000 FTU)
Accuracy0.5 FTU or 5% of reading (whichever is greater)
Calibration3 points (0 FTU, 10 FTU and 500 FTU)
Light Sourceinfrared LED
Light DetectionSilicon Photocell
Battery Type / Life1.5V AA (4) /approximately 60 hours of continuous use or 900 measurements; auto-off after 5 minutes of non-use
Environment0 to 50C (32 to 122F); RH max 95% non-condensing
Dimensions220 x 82 x 66 mm (8.7 x 3.2 x 2.6")
Weight510 g (1.1 lb.)