+30 210 82 27 825
Μάρνη 10, 10433 Αθήνα

mV 600 ORP Digital Controller

mV 600 ORP Digital Controller

The mV 600 controllers have been engineered with the same outstanding features as the pH 500 meters. The Fail Safe Alarm System protects these meters against the pitfalls of process control. User selectable timing capability safeguards against overdosing.

 

The mV 600 controllers have been engineered with the same outstanding features as the pH 500 meters. The Fail Safe Alarm System protects these meters against the pitfalls of process control. User selectable timing capability safeguards against overdosing.

  • Fully programmable
  • mA and VDC recorder output or RS232
  • Differential input for ground loop protection
  • Automatic two point calibration
  • Last calibration data
  • Automatic Temperature Compensation
  • Simple wiring with removable terminal modulesThese instruments have a differential input, extending electrode life by eliminating ground loop current through the reference. Users can choose between ON/OFF and proportional control as well as selectable current and voltage output. For more flexibility and better resolution for chart recorders, choose any two points between 0 and 2000 mV to correspond to the analog output spans.RS232 capability makes two mV 600 models PC compatible. Wiring the controllers is simple with extractable terminal modules. A host of self-testing features and user friendly functions make mV 600 a great value.Order Information:
    Each mV 600 model is supplied complete with mounting brackets and instructions.Choose your configuration
    mV 600111-2 single setpoint, on/off control, analog output, 230V

Specifications

Specifications  
RangeORP1 mV
Temperature-9.9 to 120C
ResolutionORP1 mV
Temperature0.1C
Accuracy @ 20CORP2 mV
Temperature0.5C
Input Impedance1012Ohm
ORP Calibrationautomatic, two point, at 0 and 350 or 1900 mV
Outputsdigital: RS232 bi-directional optoisolated; or analog, galvanically isolated: 0-1 mA, 0-20 mA and 4-20 mA, 0-5 VDC, 1-5 VDC and 0-10 VDC
Set Point Relay1 or 2 contact outputs SPDT 5A-250 VAC, 5A-30 VDC (resistive load), fuse protected (2A, 250V fast fuse)
Alarm Relay1 contact output SPDT, 5A-250 VAC, 5A-30 VDC (resistive load), fuse protected (2A, 250V fast fuse)
Power Supply115 VAC 10% or 230 VAC 10%; 50/60 Hz
Power Consumption15 VA
Over Current400 mA 250V fast fuse
Protection
Max Oscillation4 MHz
Frequency
Environment0 to 50C (32 to 122F); RH max 95% non-condensing
Dimensionspanel cutout: 140 x 140 mm, instrument: 144 x 144 x 170 mm
Weight1.6 kg (3.5 lb.)